Flotherm Cuts in Half the Cost of Stacked Module Potting Compound

Thermal simulation on initial concept design faster and less expensive than handling prototypes.

Thermal simulation on initial concept design faster and less expensive than handling prototypes.

By DE Editors


C-MAC reduces cost of stacked module potting compound by 50 percent using Flotherm.

C-MAC MicroTechnology (Great Yarmouth, UK) used Flomerics’ (Marlborough, MA) Flotherm thermal simulation software to determine that the thermal requirements of a stacked module could be met with a potting compound that cost only half the amount of the default choice.

C-MAC, an electronics design and manufacturing company, recently developed a stacked module for a critical defense application. Prior to building prototypes, C-MAC engineers performed thermal simulation on the initial concept design and discovered that junction temperatures on the module ranged up to 125 degrees C, well above the 100 degrees C maximum.

C-MAC realized it needed a potting compound to reduce thermal resistance and wanted to select the least expensive formulation that would meet the thermal requirements of the application. Compound type: simulated junction temperature — Standard (110 degrees C); Enhanced (85 degrees C); and Best (75 degrees C).

For more information about Flotherm, visit Flomerics.

Sources: Press materials received from the company and additional information gleaned from the company’s website.

Share This Article

Subscribe to our FREE magazine, FREE email newsletters or both!

Join over 90,000 engineering professionals who get fresh engineering news as soon as it is published.


About the Author

DE Editors's avatar
DE Editors

DE’s editors contribute news and new product announcements to Digital Engineering.
Press releases may be sent to them via [email protected].

Follow DE

Related Topics

Simulate   News   All topics
#8388